Fire flow water consumption in sprinklered and unsprinklered buildings: an assessment of community impacts

"The study considered standard estimates of the amount of water expected to be used in various building types with and without automatic sprinkler protection during a fire condition and also estimated the water used per year for commissioning, inspection, testing and maintenance of buildings with systems for each building type. The total amount of water anticipated to be used for fire protection was compared with fees in sample jurisdictions; methods were developed to calculate fire water fees that are proportional to the anticipated volume of fire water used.".

Open All Close All

http://schema.org/description

  • "Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings offers a detailed analysis for calculating the fire water demand required in buildings with existing and non-existant sprinkler systems. The installation of automatic sprinkler systems can significantly reduce the amount of water needed during a fire, but it requires water for commissioning, inspection, testing, and maintenance (CITM). This book provides an estimate of fire water used under both fire conditions, including CITM, to allow communities to develop fire water fees for both sprinklered and unsprinklered buildings that are proportional to the anticipated fire water usage. The types of buildings analyzed include residential (family dwellings as well as those up to four stories in height), business, assembly, institutional, mercantile, and storage facilities. Water volume was studied using guidelines from the International Code Council, the National Fire Protection Association, and the Insurance Services Office. Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings is intended for practitioners as a tool for analyzing water consumption in fire situations and for providing them with key information on the best types of water systems in a variety of buildings. Researchers working in building planning and safety will also find the book valuable."
  • ""The study considered standard estimates of the amount of water expected to be used in various building types with and without automatic sprinkler protection during a fire condition and also estimated the water used per year for commissioning, inspection, testing and maintenance of buildings with systems for each building type. The total amount of water anticipated to be used for fire protection was compared with fees in sample jurisdictions; methods were developed to calculate fire water fees that are proportional to the anticipated volume of fire water used."."@en

http://schema.org/genre

  • "Electronic books"

http://schema.org/name

  • "Fire flow water consumption in sprinklered and unsprinklered buildings: an assessment of community impacts"@en
  • "Fire flow water consumption in sprinklered and unsprinklered buildings an assessment of community impacts"
  • "Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings An Assessment of Community Impacts"
  • "Fire flow water consumption in sprinklered and unsprinklered buildings : an assessment of community impacts"