. . . . . . "Evaluation of air leakage control measures to compartmentalize newly constructed suites in a high-rise residential building" . "Evaluation of air leakage control measures to compartmentalize newly constructed suites in a high-rise residential building"@en . . . "Evaluation of air leakage control measures to compartmentalize newly constructed suites in a high-rise residenial building" . . . . . "Both practical experience and research have shown that air movement from floor to floor and suite to suite is relatively common in multi-unit residential buildings (MURBs). There is little practical knowledge available regarding how easily internal partititions between suites, and between suites and common areas could be sealed. CMHC initiated a research project to assess the extent to which suites could be air sealed from one another, from other adjacent interior areas, and from the outdoors, using readily available technologies and construction practices."@en . . . .