WorldCat Linked Data Explorer

http://worldcat.org/entity/work/id/793869030

Test no. 109 density of liquids and solids

This Test Guideline lists methods for determining the density of liquids and solids, giving only a succinct description of them. The density of a substance is the quotient of its mass and its volume and is expressed in SI units as kg/m3 at a specified temperature. Several methods are for liquid substance only: hydrometer, immersed body method (both are buoyancy methods) and oscillating densitometer. These methods are applicable to liquids with a dynamic viscosity below 5 Pa.s for hydrometer and oscillating densitometer and below 20 Pa.s for immersed body method. The method for solids only is the air comparison pycnometer, and pour and tap. The methods for both liquids and solids are the hydrostatic balance (a buoyancy method) and the pycnometer. The dynamic viscosity of liquids to be investigated should not exceed 5 Pa.s for the hydrostatic balance, and should not be above 500 Pa.s for the pycnometer.

Open All Close All

http://schema.org/alternateName

  • "Density of liquids and solids"@en

http://schema.org/description

  • "This Test Guideline lists methods for determining the density of liquids and solids, giving only a very succinct description of them. The density of a substance is the quotient of its mass and its volume and is expressed in kg/m3. Several methods are for liquid substance only: hydrometer, immersed body method (both are buoyancy methods) and oscillating densitometer. These methods are applicable to liquids with a dynamic viscosity below 5 Pa s for hydrometer and oscillating densitometer and below 20 Pa s for immersed body method. The method for solids only is the air comparison pycnometer. The volume of a sample of the solid is measured in air or in an inert gas in a calibrated cylinder of variable volume. After concluding the volume measurement, the sample is weighed. The methods for liquids and solids are the hydrostatic balance (a buoyancy method) and the pycnometer. The dynamic viscosity of liquids to be investigated should not exceed 5 Pa s for hydrostatic balance, and should not be above 500 Pa s for pycnometer."
  • "This Test Guideline lists methods for determining the density of liquids and solids, giving only a succinct description of them. The density of a substance is the quotient of its mass and its volume and is expressed in SI units as kg/m3 at a specified temperature. Several methods are for liquid substance only: hydrometer, immersed body method (both are buoyancy methods) and oscillating densitometer. These methods are applicable to liquids with a dynamic viscosity below 5 Pa.s for hydrometer and oscillating densitometer and below 20 Pa.s for immersed body method. The method for solids only is the air comparison pycnometer, and pour and tap. The methods for both liquids and solids are the hydrostatic balance (a buoyancy method) and the pycnometer. The dynamic viscosity of liquids to be investigated should not exceed 5 Pa.s for the hydrostatic balance, and should not be above 500 Pa.s for the pycnometer."@en

http://schema.org/name

  • "Test no. 109 density of liquids and solids"@en
  • "Test No. 109: Density of Liquids and Solids"